Ring Blowers
HRB - 402SMP · 402MP HRB - 402S · 402 Three Phase(3ø)
H&H Electric is supplying high-efficiency and high-quality products
through continuous technological development.
- HRB-402SMP
- CAD file download PDF file download
- HRB-402S
- CAD file download PDF file download
- HRB-402MP
- CAD file download PDF file download
- HRB-402
- CAD file download PDF file download
Dimensions

- The dimension is managed to around ±5mm.
- The dimension may be changed without notice for performance improvement.
Belt Driven Blowers
- The MP series is an IE3 grade product according to the International Efficiency (IE) standard grade of the International Electrical Standards Conference (IEC).
| HRB-402SMP | HRB-402S | HRB-402MP | HRB-402 | |||||||
| 50Hz | 60Hz | 50Hz | 60Hz | 50Hz | 60Hz | 50Hz | 60Hz | |||
| PHASE | 3 | 3 | 3 | 3 | ||||||
| MOTOR | HP | 2.0 | 2.3 | 2.0 | 2.3 | 3.0 | 3.4 | 3.0 | 3.4 | |
| Kw | 1.5 | 1.75 | 1.5 | 1.75 | 2.2 | 2.55 | 2.2 | 2.55 | ||
| PRESSURE | mmAq | 2500 | 2800 | 2500 | 2800 | 3500 | 4000 | 3500 | 4000 | |
| VACUUM | mmAq | 2400 | 2800 | 2400 | 2800 | 2600 | 3000 | 2600 | 3000 | |
| MAX. AIR FLOW | ㎥/min | 2.5 | 3.2 | 2.5 | 3.2 | 2.5 | 3.2 | 2.5 | 3.2 | |
| CURRENT | 220V | A | 5.5 | 7.2 | 7.6 | 8.3 | 7.1 | 9.4 | 9.5 | 10.9 |
| 380V | A | 3.1 | 4.0 | 4.4 | 4.8 | 4.0 | 5.4 | 5.6 | 6.3 | |
| SOUND LEVEL | dB(A) | 75 | 75 | 75 | 75 | |||||
| MATERIAL | IMPELLER | Aluminum | Aluminum | Aluminum | Aluminum | |||||
| CASING | Aluminum | Aluminum | Aluminum | Aluminum | ||||||
| BEARING | FRONT | 6204ZC3 | 6204ZC3 | 6204ZC3 | 6204ZC3 | |||||
| MIDDLE | 6006ZC3 | 6006ZC3 | 6006ZC3 | 6006ZC3 | ||||||
| REAR | 6305ZC3 | 6305ZC3 | 6305ZC3 | 6305ZC3 | ||||||
| WEIGHT | Kg | 34 | 34 | 38 | 38 | |||||
| STARTING CLASS | K | K | K | K | ||||||
| INSULATION CLASS | F | F | F | F | ||||||
- The above performance is based on standard condition of ambient temperature 20℃ and atmospheric pressure of 1,013 mbar.
- The performance tolerance is ±10%.
- The noise is measured at distance of 1.5 m with the inlet and outlet completely open.
- Inquire about ring blowers that require special treatment such as corrosion treatment or use of explosion-proof motors.
Performance Curve

- Continuous operation around the rated pressure may damage the motor due to overheating, so appropriate measures such as installing a relief valve are required( refer to the parts and the accessories page).
- The performance tolerance is ±10%.