Go to Contents

Product

Ring Blowers

HRB - 402SMP · 402MP HRB - 402S · 402 Three Phase(3ø)

H&H Electric is supplying high-efficiency and high-quality products through continuous technological development.
Dimensions
  • The dimension is managed to around ±5mm.
  • The dimension may be changed without notice for performance improvement.
Belt Driven Blowers
  • The MP series is an IE3 grade product according to the International Efficiency (IE) standard grade of the International Electrical Standards Conference (IEC).
TABLE
  HRB-402SMP HRB-402S HRB-402MP HRB-402
50Hz 60Hz 50Hz 60Hz 50Hz 60Hz 50Hz 60Hz
PHASE 3 3 3 3
MOTOR HP 2.0 2.3 2.0 2.3 3.0 3.4 3.0 3.4
Kw 1.5 1.75 1.5 1.75 2.2 2.55 2.2 2.55
PRESSURE mmAq 2500 2800 2500 2800 3500 4000 3500 4000
VACUUM mmAq 2400 2800 2400 2800 2600 3000 2600 3000
MAX. AIR FLOW ㎥/min 2.5 3.2 2.5 3.2 2.5 3.2 2.5 3.2
CURRENT 220V A 5.5 7.2 7.6 8.3 7.1 9.4 9.5 10.9
380V A 3.1 4.0 4.4 4.8 4.0 5.4 5.6 6.3
SOUND LEVEL dB(A) 75 75 75 75
MATERIAL IMPELLER Aluminum Aluminum Aluminum Aluminum
CASING Aluminum Aluminum Aluminum Aluminum
BEARING FRONT 6204ZC3 6204ZC3 6204ZC3 6204ZC3
MIDDLE 6006ZC3 6006ZC3 6006ZC3 6006ZC3
REAR 6305ZC3 6305ZC3 6305ZC3 6305ZC3
WEIGHT Kg 34 34 38 38
STARTING CLASS K K K K
INSULATION CLASS F F F F
  • The above performance is based on standard condition of ambient temperature 20℃ and atmospheric pressure of 1,013 mbar.
  • The performance tolerance is ±10%.
  • The noise is measured at distance of 1.5 m with the inlet and outlet completely open.
  • Inquire about ring blowers that require special treatment such as corrosion treatment or use of explosion-proof motors.
Performance Curve
  • Continuous operation around the rated pressure may damage the motor due to overheating, so appropriate measures such as installing a relief valve are required( refer to the parts and the accessories page).
  • The performance tolerance is ±10%.