Go to Contents

Product

Ring Blowers

HRB - 502MP · 602MP · 702MP HRB - 502 · 602 · 702 Three Phase(3ø)

H&H Electric is supplying high-efficiency and high-quality products through continuous technological development.
Dimensions
  • The dimension is managed to around ±5mm.
  • The dimension may be changed without notice for performance improvement.
Performance & Specifications
  • The MP series is an IE3 grade product according to the International Efficiency (IE) standard grade of the International Electrical Standards Conference (IEC).
TABLE
  HRB-502MP HRB-502 HRB-602MP HRB-602 HRB-702MP HRB-702
50Hz 60Hz 50Hz 60Hz 50Hz 60Hz 50Hz 60Hz 50Hz 60Hz 50Hz 60Hz
PHASE 3 3 3 3 3 3
MOTOR HP 3.0 3.4 3.0 3.4 4.0 5.0 4.0 5.0 5.3 6.0 5.3 6.0
Kw 2.2 2.55 2.2 2.55 3.0 3.7 3.0 3.7 4.0 4.5 4.0 4.5
PRESSURE mmAq 2700 3000 2700 3000 3800 4200 3800 4200 4500 5000 4500 5000
VACUUM mmAq 2200 2800 2200 2800 3300 4000 3300 4000 3700 4300 3700 4300
MAX. AIR FLOW ㎥/min 3.4 4.1 3.4 4.1 3.4 4.1 3.4 4.1 3.4 4.1 3.4 4.1
CURRENT 220V A 8.1 10.7 10.4 11.8 11.4 13.5 14.0 14.7 15.0 16.3 16.5 16.5
380V A 4.5 6.1 6.0 6.8 5.7 8.0 8.1 8.5 8.5 9.4 9.5 9.5
SOUND LEVEL dB(A) 78 78 78 78 78 78
MATERIAL IMPELLER Aluminum Aluminum Aluminum Aluminum Aluminum Aluminum
CASING Aluminum Aluminum Aluminum Aluminum Aluminum Aluminum
BEARING FRONT 6205ZC3 6205ZC3 6205ZC3 6205ZC3 6205ZC3 6205ZC3
MIDDLE 6006ZC3 6006ZC3 6006ZC3 6006ZC3 6006ZC3 6006ZC3
REAR 6305ZC3 6305ZC3 6305ZC3 6305ZC3 6305ZC3 6305ZC3
WEIGHT Kg 42 42 46 46 49 49
STARTING CLASS K K K K K K
INSULATION CLASS F F F F F F
  • The above performance is based on standard condition of ambient temperature 20℃ and atmospheric pressure of 1,013 mbar.
  • The performance tolerance is ±10%.
  • The noise is measured at distance of 1.5 m with the inlet and outlet completely open.
  • Inquire about ring blowers that require special treatment such as corrosion treatment or use of explosion-proof motors.
Performance Curve
  • Continuous operation around the rated pressure may damage the motor due to overheating, so appropriate measures such as installing a relief valve are required( refer to the parts and the accessories page).
  • The performance tolerance is ±10%.