Ring Blowers
HRB - 502MP · 602MP · 702MP HRB - 502 · 602 · 702 Three Phase(3ø)
H&H Electric is supplying high-efficiency and high-quality products
through continuous technological development.
- HRB-502MP
- CAD file download PDF file download
- HRB-502
- CAD file download PDF file download
- HRB-602MP
- CAD file download PDF file download
- HRB-602
- CAD file download PDF file download
- HRB-702MP
- CAD file download PDF file download
- HRB-702
- CAD file download PDF file download
Dimensions
- The dimension is managed to around ±5mm.
- The dimension may be changed without notice for performance improvement.
Performance & Specifications
- The MP series is an IE3 grade product according to the International Efficiency (IE) standard grade of the International Electrical Standards Conference (IEC).
HRB-502MP | HRB-502 | HRB-602MP | HRB-602 | HRB-702MP | HRB-702 | |||||||||
50Hz | 60Hz | 50Hz | 60Hz | 50Hz | 60Hz | 50Hz | 60Hz | 50Hz | 60Hz | 50Hz | 60Hz | |||
PHASE | 3 | 3 | 3 | 3 | 3 | 3 | ||||||||
MOTOR | HP | 3.0 | 3.4 | 3.0 | 3.4 | 4.0 | 5.0 | 4.0 | 5.0 | 5.3 | 6.0 | 5.3 | 6.0 | |
Kw | 2.2 | 2.55 | 2.2 | 2.55 | 3.0 | 3.7 | 3.0 | 3.7 | 4.0 | 4.5 | 4.0 | 4.5 | ||
PRESSURE | mmAq | 2700 | 3000 | 2700 | 3000 | 3800 | 4200 | 3800 | 4200 | 4500 | 5000 | 4500 | 5000 | |
VACUUM | mmAq | 2200 | 2800 | 2200 | 2800 | 3300 | 4000 | 3300 | 4000 | 3700 | 4300 | 3700 | 4300 | |
MAX. AIR FLOW | ㎥/min | 3.4 | 4.1 | 3.4 | 4.1 | 3.4 | 4.1 | 3.4 | 4.1 | 3.4 | 4.1 | 3.4 | 4.1 | |
CURRENT | 220V | A | 8.1 | 10.7 | 10.4 | 11.8 | 11.4 | 13.5 | 14.0 | 14.7 | 15.0 | 16.3 | 16.5 | 16.5 |
380V | A | 4.5 | 6.1 | 6.0 | 6.8 | 5.7 | 8.0 | 8.1 | 8.5 | 8.5 | 9.4 | 9.5 | 9.5 | |
SOUND LEVEL | dB(A) | 78 | 78 | 78 | 78 | 78 | 78 | |||||||
MATERIAL | IMPELLER | Aluminum | Aluminum | Aluminum | Aluminum | Aluminum | Aluminum | |||||||
CASING | Aluminum | Aluminum | Aluminum | Aluminum | Aluminum | Aluminum | ||||||||
BEARING | FRONT | 6205ZC3 | 6205ZC3 | 6205ZC3 | 6205ZC3 | 6205ZC3 | 6205ZC3 | |||||||
MIDDLE | 6006ZC3 | 6006ZC3 | 6006ZC3 | 6006ZC3 | 6006ZC3 | 6006ZC3 | ||||||||
REAR | 6305ZC3 | 6305ZC3 | 6305ZC3 | 6305ZC3 | 6305ZC3 | 6305ZC3 | ||||||||
WEIGHT | Kg | 42 | 42 | 46 | 46 | 49 | 49 | |||||||
STARTING CLASS | K | K | K | K | K | K | ||||||||
INSULATION CLASS | F | F | F | F | F | F |
- The above performance is based on standard condition of ambient temperature 20℃ and atmospheric pressure of 1,013 mbar.
- The performance tolerance is ±10%.
- The noise is measured at distance of 1.5 m with the inlet and outlet completely open.
- Inquire about ring blowers that require special treatment such as corrosion treatment or use of explosion-proof motors.
Performance Curve
- Continuous operation around the rated pressure may damage the motor due to overheating, so appropriate measures such as installing a relief valve are required( refer to the parts and the accessories page).
- The performance tolerance is ±10%.